A01Ignition failure🔄 Try Reset
The boiler has failed to establish a flame after multiple ignition attempts.
A02Flame loss🔄 Try Reset
The boiler established a flame but it extinguished unexpectedly during operation.
A03Overheating — safety🔧 Engineer Required
The safety thermostat has tripped due to excessive boiler temperature.
A04Overheating — high limit🔧 Engineer Required
The high limit thermostat has activated, indicating the boiler has overheated.
A05Flue gas thermostat🔧 Engineer Required
The flue gas thermostat has detected an abnormal flue temperature.
A10Low water pressure🔄 Try Reset
System water pressure has dropped below the minimum required level.
A16Fan fault🔧 Engineer Required
The combustion fan is not operating at the correct speed.
A37No water flow detected🔧 Engineer Required
The boiler cannot detect adequate water flow through the heat exchanger.